Pogodina Ekaterina Alexandrovna (General Director, Biologist of the KLD Scientific and Medical Laboratory "Aliquot"
Federal State Budgetary Institution "Research Institute of Vaccines and Serums named after I.I. Mechnikov" of the Ministry of Health of the Russian Federation
)
Lobov Anton Viktorovich (Medical Director, Doctor of the KLD Scientific and Medical Laboratory "Aliquot"
Federal State Budgetary Institution "Research Institute of Vaccines and Serums named after I.I. Mechnikov" of the Ministry of Health of the Russian Federation
)
Ivanova Polina Igorevna (Head of the Clinical Diagnostic Laboratory, Biologist of the Clinical Diagnostic Laboratory of the Scientific and Medical Laboratory "Aliquot"
Federal State Budgetary Institution "Research Institute of Vaccines and Serums named after I.I. Mechnikov" of the Ministry of Health of the Russian Federation
)
Golovnya Evgeniy Gennadievich (Researcher of the Scientific and Medical Laboratory "Aliquot")
Sorokina Ekaterina Vyacheslavovna (Doctor of Medical Sciences, Head of the Laboratory of Immunity Regulation Mechanisms, Dermatovenerologist
Federal State Budgetary Institution "Research Institute of Vaccines and Serums named after I.I. Mechnikov" I. I. Mechnikov" of the Ministry of Health of the Russian Federation
)
|
Assessment of menstrual blood loss is crucial for the diagnosis and management of gynecological diseases, but there is no standardized laboratory test to accurately quantify menstrual blood loss. The aim of this study was to evaluate and optimize the alkaline-hematin test for the assessment of menstrual blood loss using modern laboratory equipment. Five female volunteers who provided used menstrual hygiene products during one complete menstrual cycle participated in the study. The samples were subjected to alkaline extraction and hemoglobin concentration was measured using a Tecan Infinite f50 spectrophotometer. Before the main study, we tested whether the brand of hygiene product affected the results of hemoglobin extraction and verified that there were no significant differences between different brands of products. The results showed different amounts of menstrual blood loss in the volunteers and correlated with the gynecological history of the volunteers. The study confirmed the feasibility of using the alkaline-hematin test to quantify menstrual blood loss, demonstrating its potential application in clinical practice. However, further validation with the involvement of more volunteers is needed to establish reference values, optimize sample collection methods, and develop a universal algorithm for recalculating results for use in clinical practice and for patients. This method can serve as a valuable diagnostic tool that will allow an objective assessment of the amount of blood loss, and can also be used as a marker of the effectiveness of therapy.
Keywords:menstruation, anemia, laboratory diagnostics, oncology
|
|
|
Read the full article …
|
Citation link: Pogodina E. A., Lobov A. V., Ivanova P. I., Golovnya E. G., Sorokina E. V. DEVELOPMENT AND VALIDATION OF A METHOD FOR ESTIMATING MENSTRUAL BLOOD LOSS BASED ON ALKALINE-HAEMATIN EXTRACTION // Современная наука: актуальные проблемы теории и практики. Серия: Естественные и Технические Науки. -2025. -№05. -С. 244-230 DOI 10.37882/2223-2966.2025.05.30 |
|
|